tracker

2436 Modular (Vertical) Replacement Instructions

2 or 2.5 Ton Replacement

Component Straight AC HP
Blower M2430BL2-EC2
Coil M2430CL1-BA001 M2430CL1-E001
Hot Water Coil (if applicable) HW-2430
Chilled Water Coil (if applicable) M2430CL1-C
Vertical Stand M2430V2
R32 Valve TXV-2T-32
R454 Valve TXV-2T-454
 
Notes: Requires a minimum 7″ main plenum, 14″ return, and 6 outlets per ton.

3 Ton Replacement

Component Straight AC HP
Blower M3036BL2-EC2
Coil M3036CL1-BA001 M3036CL1-E001
Hot Water Coil (if applicable) HW-3036
Vertical Stand M3036V2
R32 Valve TXV-3T-32
R454 Valve TXV-3T-454
 
Notes: Requires a minimum 9″ main plenum, 16″ return, and 6 outlets per ton.

Replacement Parts

Part Straight AC HP
Motor A00138-001 (8WV09) A00054-001 (8WV20)
Wheel A00137-001 A00082-002
Relay A00056-G02
Transformer A02701-K01
Frost Switch A00060-K03
Hot Water Coil (HW-2436) HW-2430