tracker

VP-4860 Replacement Instructions

4 Ton Replacement

Component Straight AC HP
Blower M3642BL2-EC2
Coil M3642CL1-BA001 M3642CL1-E001
Hot Water Coil (if applicable) HW-3642
Vertical Stand M3642V2
R32 Valve TXV-4T-32
R454 Valve TXV-4T-454
Notes: Requires a minimum 9″ main plenum, 18″ return, and 6 outlets per ton.

5 Ton Replacement

Component Straight AC HP
Blower M4860BL2-EC2
Coil M4860CL1-B001 M4860CL1-B001
Hot Water Coil (if applicable) HW-4860
R32 Valve TXV-5T-32
R454 Valve TXV-5T-454
Notes: Requires a minimum 10″ main plenum, 20″ return, and 6 outlets per ton.

Replacement Parts

Part Part Number
Motor A00141-001 (8WV21)
Wheel A00036-002
Relay A00056-G02
Transformer A02701-K01
Frost Switch A00060-K03